Bentley Substation CONNECT Edition Setup Guide - ProjectWise Managed Configuration

Create a new "Predefined" level CSB for Bentley Substation called Substation_Configuration_CE

This CSB will make the vital connection between the CSBs and the ProjectWise datasource.
  1. In ProjectWise Administrator, under WorkSpaces > Managed > Predefined right-click over the Predefined Level and select New > Configuration Block.
  2. In the New Configuration Block Properties, enter the name Substation_Configuration_Root and the description Substation CONNECT Edition Configuration Root. Once complete, click Apply.

    The dialog title will change to Substation_Configuration_CE Properties.

  3. Add the following variables and/or directives:

    Add Variable to theSubstation_Configuration_Root Root CSB

    Name _USTN_CONFIGURATION
    Description Bentley Substation PW Configuration (_USTN_CONFIGURATION)
    Add Value Operation Type: '='- Assignment

    Value Type: ProjectWise Folder

    Value: Change value to point to ProjectWise Configuration, browse to pw:\\<server name>:<datasource name>\Documents\Substation_Managed_Configuration \
    Locked YES
    Note: _USTN_CONFIGURATION defines the folder containing the entire Managed Configuration.
    Tip: Since Configurations can be version specific, the Substation_Configuration_Root Properties CSB includes the CE (CONNECT Edition) moniker to designate and differentiate between configuration versions.